The first properly cold evening of the year is when most people find out their heating has a problem. The boiler fires, the pipes tick, and yet the front room radiator stays stone cold, or the house never gets past lukewarm. Before you pick up the phone, a few simple checks will either fix it or tell you exactly what to describe when you do.

First, the five-minute checks

Work through these in order. Each one takes a minute and none of them needs tools.

  1. Is the heating actually asking for heat? Turn the room thermostat up a few degrees above the temperature in the room. You should hear a click, and the boiler should start within a minute or so.
  2. Is the timer on? After a power cut, or when the clocks changed in October, many programmers lose their settings or run an hour out. Switch the heating to constant or boost to rule this out.
  3. Are the radiator valves open? The valve with numbers on it (the thermostatic one) should be turned up, not set to the snowflake or zero. Valves that have not moved all summer can stick shut; turn the head fully up and down a couple of times.
  4. What does the pressure gauge say? On a combi or sealed system there is a small dial on the front or underneath. The handbook, or a green band on the dial, shows the normal range. If the needle has dropped low, the boiler may refuse to heat at all.
  5. Is there a fault light or code on the display? Write it down. It is the most useful thing you can tell us.

If a check turns something up, put it right and give the system twenty minutes to warm through before deciding whether it worked.

Reading the radiators

Once the boiler is running, feel each radiator carefully with the flat of your hand. Where the cold patch sits tells you a lot.

  • Cold at the top, warm below: trapped air. Bleed it (see below).
  • Warm along the top, cold at the bottom: sludge has settled inside the panel.
  • One radiator cold, the rest fine: a stuck valve, a blocked inlet, or that radiator simply is not getting its share of the flow.
  • Radiators furthest from the boiler are cooler: the system needs balancing, so the nearest ones are not taking all the heat.
  • Every radiator cold, hot water fine: the fault is likely in the controls, the pump or the valve that switches between heating and hot water.

How to bleed a radiator safely

Switch the heating off and wait until the radiators are cool. Fit a radiator key into the small square valve at the top corner of the panel, hold a folded cloth under it, and turn anticlockwise a quarter to half a turn. You will hear air hiss out. The moment water starts to dribble, close it again.

Bleeding lets water out with the air, so on a sealed system check the pressure gauge afterwards. If it has fallen below the normal range and your boiler handbook shows how to top it up using the filling loop, follow those steps exactly. If there is no handbook, or you are unsure which valves to open, leave it and call.

What not to do

  • Do not take the boiler casing off or try to reset anything inside it. Use only the controls on the outside.
  • Do not open a bleed valve while the system is hot.
  • Do not keep topping up the pressure every day. A system that keeps losing pressure has a leak or a faulty part somewhere, and adding more water just hides it.
  • Do not run electric heaters off a chain of extension leads while you wait; a single heater plugged straight into a wall socket is far safer.
  • Do not ignore water dripping from a radiator valve or pipe joint.

If water is leaking

A weeping valve can usually be managed with a bowl and a towel until morning. A steady drip or a spray is different: turn off the heating, turn off the water at the stopcock, keep the water away from sockets and light fittings, and ring us. Our guide on what to do when a pipe bursts covers making a leak safe step by step.

Why heating plays up in Manchester homes

A lot of housing across Greater Manchester and north Cheshire still runs on systems fitted decades ago. Victorian and Edwardian terraces in places like Levenshulme, Eccles and Stockport often had heating added long after they were built, with long pipe runs under floorboards and radiators of every age on the same circuit. Inter-war semis in Sale, Urmston and Stretford may have an old cylinder and a loft tank feeding the heating, where air locks are common. Flats tend to have compact combis and short pipe runs, where low pressure is the usual culprit. Older steel radiators on any of these systems slowly fill with sludge.

When to ring, and what happens then

Call or WhatsApp 07893 933403 if the checks above have not brought the heat back, if the boiler shows a fault code you cannot clear, if the pressure keeps falling, or if anything is leaking. A photo of the display or the dripping valve on WhatsApp helps us bring the right parts.

We aim to be with you within 60 minutes. The engineer starts with the same questions you have just answered, then traces the fault: bleeding and balancing the system, freeing or replacing a sticking valve, checking the pump and controls, flushing a sludged radiator, or repairing the boiler itself. Before any part is fitted, you are told what it is and what it costs. Our plumbing page lists the rest of the water and heating work we take on, and in the Altrincham, Hale and Timperley area our Altrincham plumbers page covers that patch.

The time is charged by the hour and the same rate applies on a frosty Sunday night: £89 gets you the first hour, £45 each half hour after that, no fee for turning up, and parts only if you need them.

Keeping the heating healthy through winter

  • Run the heating for a short spell once in early autumn, so you find a problem before the first cold night rather than on it.
  • Turn every radiator valve fully on and off once a year so they do not seize.
  • Glance at the pressure gauge every few weeks and note where the needle normally sits.
  • Bleed radiators that develop cold tops, and keep track of which ones need it often.
  • Keep the area around the boiler clear, so it can be reached quickly if it ever needs attention.

Heating help across Greater Manchester

Cold radiators are our most common winter heating call in Stockport, Sale and Didsbury, where many homes still run the original 1960s and 70s pipework. If a pipe has split under the floor while you were checking, stop the water first.

Questions people ask

Why is my radiator hot at the bottom but cold at the top?

That is almost always air collecting in the top of the panel. Heating water carries tiny amounts of air round the system, and it gathers at the highest point it can reach. Bleeding the radiator with a key lets the air out and the panel fills with hot water again. If the same radiator needs bleeding every week or two, something is drawing air into the system and it is worth having it looked at.

Why is my radiator warm at the top but cold along the bottom?

A panel that heats along the top edge while the lower half stays cool is usually holding sludge, the black silt that builds up inside older steel radiators. Bleeding will not help with this. The radiator needs flushing through, or sometimes the whole system needs cleaning, which is a job for us rather than for you.

Only the upstairs radiators are cold. What does that mean?

In a house with a hot water cylinder and a tank in the loft, cold upstairs radiators often point to air trapped high in the system, a pump that is struggling, or a sticking valve that decides which part of the house gets heat. Bleed the upstairs radiators first. If they stay cold with the heating on, ring us and describe which rooms are warm and which are not.

Is it safe to bleed a radiator myself?

Yes, as long as the heating is switched off and the radiators have cooled down first. Hot water under pressure can scald, so never open a bleed valve on a hot radiator. Hold a cloth under the key, open the valve no more than half a turn, and close it as soon as water appears.

How much will it cost if you have to come out?

One rate covers it, whatever the trade or the hour: £89 for the first hour on site and £45 for each half hour after that. There is no call-out fee and any parts are added on top. Our pricing page shows the full table.

Why is my radiator cold at the bottom but warm at the top?

That pattern usually means sludge, a build-up of rust and debris, has settled along the bottom of the radiator and is stopping water flowing through it. Bleeding will not cure it. The radiator needs flushing, or the whole system needs a power flush and a magnetic filter if several radiators show the same thing.

Why do my radiators not heat up when the boiler is on?

If the boiler fires but nothing gets warm, the usual suspects are a failed circulating pump, a motorised valve stuck shut, or low system pressure. Check the pressure gauge first: around 1 to 1.5 bar cold is typical on a sealed system. If the pressure is fine, the pump or valve needs looking at.